S W Seabrook Catfish Ponds Reservoir Report

Last Updated: December 5, 2025

S W Seabrook Catfish Ponds in Tunica, Mississippi, is a private water resource managed by the USDA NRCS and completed in 1969.


°F

°F

mph

Wind

%

Humidity

Summary

The primary purpose of this Earth type dam is for catfish farming, with a storage capacity of 400 acre-feet and a spillway width of 2 feet. Located on TR- BEAVERDAM BAYOU, this significant hazard potential structure has a moderate risk rating and lacks a formal condition assessment.

While S W Seabrook Catfish Ponds has not been regulated or inspected by state agencies, it serves as a vital resource for catfish production in the region. With an uncontrolled spillway and outlet gates, the dam's hydraulic height stands at 8 feet, with a length of 9220 feet. The surrounding area, known for its water-rich environment, provides an ideal setting for the successful cultivation of catfish, enhancing the local economy and agricultural landscape.

As water resource and climate enthusiasts explore the intricate details of S W Seabrook Catfish Ponds, they can appreciate the engineering behind its construction and the role it plays in sustaining the catfish industry. The collaboration between private ownership and federal agencies like the USDA NRCS showcases the importance of maintaining and managing water resources for both economic and environmental sustainability in Mississippi's diverse landscape.

Year Completed

1969

Dam Length

9220

Dam Height

8

River Or Stream

TR- BEAVERDAM BAYOU

Primary Dam Type

Earth

Hydraulic Height

8

Nid Storage

400

Outlet Gates

Uncontrolled

Hazard Potential

Significant

Foundations

Soil

Nid Height

8
       
Seasonal Comparison

Weather Forecast

Dam Data Reference

Condition Assessment

Satisfactory
No existing or potential dam safety deficiencies are recognized. Acceptable performance is expected under all loading conditions (static, hydrologic, seismic) in accordance with the minimum applicable state or federal regulatory criteria or tolerable risk guidelines.
Fair
No existing dam safety deficiencies are recognized for normal operating conditions. Rare or extreme hydrologic and/or seismic events may result in a dam safety deficiency. Risk may be in the range to take further action. Note: Rare or extreme event is defined by the regulatory agency based on their minimum
Poor A dam safety deficiency is recognized for normal operating conditions which may realistically occur. Remedial action is necessary. POOR may also be used when uncertainties exist as to critical analysis parameters which identify a potential dam safety deficiency. Investigations and studies are necessary.
Unsatisfactory
A dam safety deficiency is recognized that requires immediate or emergency remedial action for problem resolution.
Not Rated
The dam has not been inspected, is not under state or federal jurisdiction, or has been inspected but, for whatever reason, has not been rated.
Not Available
Dams for which the condition assessment is restricted to approved government users.

Hazard Potential Classification

High
Dams assigned the high hazard potential classification are those where failure or mis-operation will probably cause loss of human life.
Significant
Dams assigned the significant hazard potential classification are those dams where failure or mis-operation results in no probable loss of human life but can cause economic loss, environment damage, disruption of lifeline facilities, or impact other concerns. Significant hazard potential classification dams are often located in predominantly rural or agricultural areas but could be in areas with population and significant infrastructure.
Low
Dams assigned the low hazard potential classification are those where failure or mis-operation results in no probable loss of human life and low economic and/or environmental losses. Losses are principally limited to the owner's property.
Undetermined
Dams for which a downstream hazard potential has not been designated or is not provided.
Not Available
Dams for which the downstream hazard potential is restricted to approved government users.