Eldon Cordell Structure Dam Reservoir Report

Last Updated: December 15, 2025

The Eldon Cordell Structure Dam, located in Ravenwood, Missouri, was completed in 1967 and serves as a key component for grade stabilization along the TR-Honey Creek.


°F

°F

mph

Wind

%

Humidity

Summary

This privately-owned Earth dam stands at a height of 29 feet and has a structural height of 30 feet, with a length of 450 feet. The dam has a low hazard potential and is not currently rated for its condition assessment.

With a normal storage capacity of 14 acre-feet and a maximum storage of 26 acre-feet, the Eldon Cordell Structure Dam plays a crucial role in managing water resources in the area. Its uncontrolled spillway with a width of 28 feet helps regulate water flow, with a max discharge of 170 cubic feet per second. Despite being privately owned, the dam is not regulated by the state and does not require regular inspections, reflecting its relatively low risk profile.

For water resource and climate enthusiasts, the Eldon Cordell Structure Dam represents a fascinating example of how private infrastructure plays a role in managing water resources and mitigating risks. With a moderate risk assessment score and a focus on grade stabilization, this Earth dam showcases the importance of maintaining and monitoring critical infrastructure to ensure the safety and sustainability of water systems in Nodaway, Missouri.

Year Completed

1967

Dam Length

450

Dam Height

29

River Or Stream

TR-HONEY CREEK

Primary Dam Type

Earth

Surface Area

6

Hydraulic Height

28

Drainage Area

230.4

Nid Storage

26

Structural Height

30

Outlet Gates

None

Hazard Potential

Low

Foundations

Soil

Nid Height

30
       
Seasonal Comparison

Weather Forecast

Dam Data Reference

Condition Assessment

Satisfactory
No existing or potential dam safety deficiencies are recognized. Acceptable performance is expected under all loading conditions (static, hydrologic, seismic) in accordance with the minimum applicable state or federal regulatory criteria or tolerable risk guidelines.
Fair
No existing dam safety deficiencies are recognized for normal operating conditions. Rare or extreme hydrologic and/or seismic events may result in a dam safety deficiency. Risk may be in the range to take further action. Note: Rare or extreme event is defined by the regulatory agency based on their minimum
Poor A dam safety deficiency is recognized for normal operating conditions which may realistically occur. Remedial action is necessary. POOR may also be used when uncertainties exist as to critical analysis parameters which identify a potential dam safety deficiency. Investigations and studies are necessary.
Unsatisfactory
A dam safety deficiency is recognized that requires immediate or emergency remedial action for problem resolution.
Not Rated
The dam has not been inspected, is not under state or federal jurisdiction, or has been inspected but, for whatever reason, has not been rated.
Not Available
Dams for which the condition assessment is restricted to approved government users.

Hazard Potential Classification

High
Dams assigned the high hazard potential classification are those where failure or mis-operation will probably cause loss of human life.
Significant
Dams assigned the significant hazard potential classification are those dams where failure or mis-operation results in no probable loss of human life but can cause economic loss, environment damage, disruption of lifeline facilities, or impact other concerns. Significant hazard potential classification dams are often located in predominantly rural or agricultural areas but could be in areas with population and significant infrastructure.
Low
Dams assigned the low hazard potential classification are those where failure or mis-operation results in no probable loss of human life and low economic and/or environmental losses. Losses are principally limited to the owner's property.
Undetermined
Dams for which a downstream hazard potential has not been designated or is not provided.
Not Available
Dams for which the downstream hazard potential is restricted to approved government users.