Newell Lake, located in Montgomery, Alabama, serves as a key structure for grade stabilization along the TR-CATOMA CREEK.


°F

°F

mph

Wind

%

Humidity

Summary

Owned privately, this Earth-type dam stands at 9 feet high and spans a length of 620 feet, providing a storage capacity of 67 acre-feet. With a surface area of 10 acres, the lake has a maximum storage capacity of 67 acre-feet, making it a crucial component in managing water resources in the region.

Despite its importance, Newell Lake poses a high hazard potential and has not been rated for its condition assessment. Emergency action plans and risk management measures have not been fully implemented or assessed, raising concerns about the lake's safety and potential impact in case of emergencies. With no regular inspections or maintenance reported, there is a pressing need for increased attention and oversight to ensure the structure's integrity and the safety of surrounding communities.

In the Congressional District 07 of Alabama, Newell Lake stands as a significant infrastructure for water resource management. However, the lack of regulatory oversight and condition assessments raise concerns about its safety and long-term functionality. For water resource and climate enthusiasts, this data underscores the importance of proactive measures to safeguard critical structures like Newell Lake and ensure sustainable management of water resources in the region.

Dam Length

620

Dam Height

9

River Or Stream

TR-CATOMA CREEK

Primary Dam Type

Earth

Surface Area

10

Nid Storage

67

Hazard Potential

High

Nid Height

9
       
Seasonal Comparison

Weather Forecast

Dam Data Reference

Condition Assessment

Satisfactory
No existing or potential dam safety deficiencies are recognized. Acceptable performance is expected under all loading conditions (static, hydrologic, seismic) in accordance with the minimum applicable state or federal regulatory criteria or tolerable risk guidelines.
Fair
No existing dam safety deficiencies are recognized for normal operating conditions. Rare or extreme hydrologic and/or seismic events may result in a dam safety deficiency. Risk may be in the range to take further action. Note: Rare or extreme event is defined by the regulatory agency based on their minimum
Poor A dam safety deficiency is recognized for normal operating conditions which may realistically occur. Remedial action is necessary. POOR may also be used when uncertainties exist as to critical analysis parameters which identify a potential dam safety deficiency. Investigations and studies are necessary.
Unsatisfactory
A dam safety deficiency is recognized that requires immediate or emergency remedial action for problem resolution.
Not Rated
The dam has not been inspected, is not under state or federal jurisdiction, or has been inspected but, for whatever reason, has not been rated.
Not Available
Dams for which the condition assessment is restricted to approved government users.

Hazard Potential Classification

High
Dams assigned the high hazard potential classification are those where failure or mis-operation will probably cause loss of human life.
Significant
Dams assigned the significant hazard potential classification are those dams where failure or mis-operation results in no probable loss of human life but can cause economic loss, environment damage, disruption of lifeline facilities, or impact other concerns. Significant hazard potential classification dams are often located in predominantly rural or agricultural areas but could be in areas with population and significant infrastructure.
Low
Dams assigned the low hazard potential classification are those where failure or mis-operation results in no probable loss of human life and low economic and/or environmental losses. Losses are principally limited to the owner's property.
Undetermined
Dams for which a downstream hazard potential has not been designated or is not provided.
Not Available
Dams for which the downstream hazard potential is restricted to approved government users.