American Ind Clay Co Impound Dam # 1 Reservoir Report

Last Updated: December 15, 2025

American Ind Clay CO Impound Dam #1, located in Washington, Georgia, serves as a critical structure for managing tailings from industrial operations.


°F

°F

mph

Wind

%

Humidity

Summary

This private earth dam, with a height of 30 feet and a length of 1440 feet, provides a storage capacity of 19 acre-feet. While the dam has a low hazard potential, it is classified with a moderate risk level, highlighting the importance of regular inspections and maintenance.

Despite not being regulated by the state, American Ind Clay CO Impound Dam #1 undergoes periodic inspections, with the last assessment conducted in 2003. The dam features an uncontrolled spillway and outlet gates, emphasizing the need for vigilant monitoring to ensure its structural integrity. With a risk management plan that addresses the moderate risk associated with the dam, it is crucial for stakeholders to remain proactive in safeguarding this vital water resource.

As water resource and climate enthusiasts, understanding the role of dams like American Ind Clay CO Impound Dam #1 in managing industrial tailings is crucial for sustainable water management practices. With a focus on risk assessment and management, this dam serves as a reminder of the importance of maintaining infrastructure to protect against potential hazards and ensure the continued availability of water resources for future generations.

Dam Length

1440

Dam Height

30

River Or Stream

UNKNOWN

Primary Dam Type

Earth

Drainage Area

105

Nid Storage

19

Outlet Gates

Uncontrolled

Hazard Potential

Low

Foundations

Unlisted/Unknown

Nid Height

30
       
Seasonal Comparison

Weather Forecast

Dam Data Reference

Condition Assessment

Satisfactory
No existing or potential dam safety deficiencies are recognized. Acceptable performance is expected under all loading conditions (static, hydrologic, seismic) in accordance with the minimum applicable state or federal regulatory criteria or tolerable risk guidelines.
Fair
No existing dam safety deficiencies are recognized for normal operating conditions. Rare or extreme hydrologic and/or seismic events may result in a dam safety deficiency. Risk may be in the range to take further action. Note: Rare or extreme event is defined by the regulatory agency based on their minimum
Poor A dam safety deficiency is recognized for normal operating conditions which may realistically occur. Remedial action is necessary. POOR may also be used when uncertainties exist as to critical analysis parameters which identify a potential dam safety deficiency. Investigations and studies are necessary.
Unsatisfactory
A dam safety deficiency is recognized that requires immediate or emergency remedial action for problem resolution.
Not Rated
The dam has not been inspected, is not under state or federal jurisdiction, or has been inspected but, for whatever reason, has not been rated.
Not Available
Dams for which the condition assessment is restricted to approved government users.

Hazard Potential Classification

High
Dams assigned the high hazard potential classification are those where failure or mis-operation will probably cause loss of human life.
Significant
Dams assigned the significant hazard potential classification are those dams where failure or mis-operation results in no probable loss of human life but can cause economic loss, environment damage, disruption of lifeline facilities, or impact other concerns. Significant hazard potential classification dams are often located in predominantly rural or agricultural areas but could be in areas with population and significant infrastructure.
Low
Dams assigned the low hazard potential classification are those where failure or mis-operation results in no probable loss of human life and low economic and/or environmental losses. Losses are principally limited to the owner's property.
Undetermined
Dams for which a downstream hazard potential has not been designated or is not provided.
Not Available
Dams for which the downstream hazard potential is restricted to approved government users.