Corlay Lake No 2 Dam Reservoir Report

Last Updated: December 5, 2025

Corlay Lake No 2 Dam, located in Walker County, Texas, stands as a testament to engineering ingenuity and environmental stewardship.


°F

°F

mph

Wind

%

Humidity

Summary

Completed in 2008, this private-owned Earth dam serves a variety of purposes, with a primary focus on water resource management. Standing at a height of 25.9 feet and a hydraulic height of 17.9 feet, the dam boasts a storage capacity of 87 acre-feet and covers a surface area of 8.4 acres.

Despite its impressive infrastructure, recent assessments have flagged the dam's condition as poor, posing a moderate risk in need of management measures. The dam's spillway, with a width of 114 feet, is uncontrolled and equipped with four outlet gates. With a drainage area of 0.03 square miles, the dam plays a crucial role in regulating water flow from the Trinity River. However, its inadequate condition raises concerns about its long-term reliability.

As a vital component of the local water management system, Corlay Lake No 2 Dam warrants attention and potential upgrades to ensure its continued effectiveness in mitigating flood risks and preserving water resources for the surrounding community. Its location in Huntsville, Texas, makes it a focal point for water resource and climate enthusiasts keen on sustainable infrastructure development.

Year Completed

2008

Dam Length

409

Dam Height

25.9

River Or Stream

UN TR-THE TRINITY RIVER

Primary Dam Type

Earth

Surface Area

8.4

Hydraulic Height

17.9

Drainage Area

0.03

Nid Storage

87

Structural Height

25.9

Outlet Gates

Uncontrolled - 4

Hazard Potential

Not Available

Foundations

Soil

Nid Height

26
       
Seasonal Comparison

Weather Forecast

Dam Data Reference

Condition Assessment

Satisfactory
No existing or potential dam safety deficiencies are recognized. Acceptable performance is expected under all loading conditions (static, hydrologic, seismic) in accordance with the minimum applicable state or federal regulatory criteria or tolerable risk guidelines.
Fair
No existing dam safety deficiencies are recognized for normal operating conditions. Rare or extreme hydrologic and/or seismic events may result in a dam safety deficiency. Risk may be in the range to take further action. Note: Rare or extreme event is defined by the regulatory agency based on their minimum
Poor A dam safety deficiency is recognized for normal operating conditions which may realistically occur. Remedial action is necessary. POOR may also be used when uncertainties exist as to critical analysis parameters which identify a potential dam safety deficiency. Investigations and studies are necessary.
Unsatisfactory
A dam safety deficiency is recognized that requires immediate or emergency remedial action for problem resolution.
Not Rated
The dam has not been inspected, is not under state or federal jurisdiction, or has been inspected but, for whatever reason, has not been rated.
Not Available
Dams for which the condition assessment is restricted to approved government users.

Hazard Potential Classification

High
Dams assigned the high hazard potential classification are those where failure or mis-operation will probably cause loss of human life.
Significant
Dams assigned the significant hazard potential classification are those dams where failure or mis-operation results in no probable loss of human life but can cause economic loss, environment damage, disruption of lifeline facilities, or impact other concerns. Significant hazard potential classification dams are often located in predominantly rural or agricultural areas but could be in areas with population and significant infrastructure.
Low
Dams assigned the low hazard potential classification are those where failure or mis-operation results in no probable loss of human life and low economic and/or environmental losses. Losses are principally limited to the owner's property.
Undetermined
Dams for which a downstream hazard potential has not been designated or is not provided.
Not Available